Xinxiang vibrating screen factory teaches you how to solve the problem of high temperature of the vibration exciter

08-11-2023

Henan Honghe Technology Co., Ltd. is a manufacturer specializing in the production of vibrating screens. The exciter is an important component of vibrating screens, and abnormalities in the exciter are generally divided into: abnormal noise, high noise

Today, we will discuss in detail the high-temperature treatment methods and preventive measures for the vibration exciter, including temperature and oil leakage.

There are generally several methods for the cause of excessive temperature of the exciter:

1. Lack of lubricating oil, treatment method: Add oil and ensure that the oil level is displayed within the range marked on the oil level gauge or dipstick.

Preventive measures: 1.1 Weekly inspection of the oil level of the vibration exciter

1.2. The leakage exciter should be inspected daily and lubricating oil should be replenished in a timely manner

2. If there is too much lubricating oil, treatment method: Ensure that the oil level is displayed within the oil level or cursor range

Preventive measure: When refueling, keep the oil level within the displayed range

3. Lubricating oil deteriorates and emulsifies with impurities

Solution: 1. Replace the lubricating oil

Perform oil sample analysis

The breathable cap is fully installed

Bearing pitting, bearing outer ring rotation

Processing method: Replace the exciter bearing and choose large clearance (C3/C4)

Preventive measures: When disassembling and assembling, special bearings for vibration exciters must be selected.

Assembly quality issues or shaft alignment

Reassemble and adjust the assembly clearance, tighten the end cover bolts

Preventive measures: 1. Strictly assemble according to the drawing clearance

After the assembly of the vibration exciter clearance is completed, the test platform is debugged.

Regularly tighten the fixing bolts of each end cover and eccentric block.